  1. Dive Into Suction Tank Issues and Inspections

    Leave a Comment

    Privately-owned water tanks supplying fire protection systems have a long history. The NFPA published the Standard on Gravity Tanks in 1909. It is one of the oldest NFPA codes, predating even the Life Safety Code’s precursor, the Building Exits Code, first published in 1927. The Standard on Gravity Tanks evolved over the years to become NFPA 22, Standard for Water Tanks for Private Fire Protection. The inspection, testing, and maintenance requirements for all types of private fire water storage tanks are laid out in NFPA 25, Chapter 9 – Water Storage Tanks. While there are about eight different types of fire water tanks, I’d assert that the most common type today is the steel suction tank. (more…)

  2. Testing As Part of Gas Appliance Incident Investigation

    Leave a Comment

    Equipment and appliances supplied with fuel gases like natural gas, propane and butane are a common and convenient part of most of our lives.  Such devices as gas grills and ranges, ovens, furnaces, space heaters and water heaters usually perform without incident.  However, when they malfunction the potential for incidents such as fires and explosions, carbon monoxide (CO) poisoning and burn injuries may occur. These incidents may be due to design and manufacturing defects in the product, or improper installation or operation of the device.

    (more…)

  3. Crawler Crane Calamity at Cement Plant

    Leave a Comment

    A production building was being constructed at a cement plant.  A large crawler crane was being used to install the pre-assembled metal wall framing of the building.  The weights and lift radii of the four wall framing sections, along with the rigging spreader and other lift equipment, were within the rated capacity of the crane. (more…)

  4. Crane Pile Driving: Who Owns This Loss?

    Leave a Comment

    The boom of a hydraulic crane was bent while removing temporary sheet piles at a construction site.  A vibratory hammer had been placed at the top of the sheet piles to both drive and remove the piles. The vibratory pile driving placed no significant loads on the crane boom, as that operation relied on the weight of the sheet piles and the vibration of the hammer to sink the piles into the soil.  The vibration of the hammer and the lifting force of the crane boom were needed to remove the sheet piles from the soil. (more…)

  5. Mobile Crane Ground Support

    Leave a Comment

    Mobile cranes depend on stability through their outriggers. These are the four “legs” that are deployed onto soil or other working surfaces adjacent to the crane.  When a mobile crane is set up at a site, the outriggers are deployed by a hydraulic mechanism that extends the four outriggers beyond the crane body and then jack the crane free of its wheels so that it is supported by the outriggers only. (more…)

  6. Code Violations Are Root of Fatal Explosion

    Leave a Comment

    The design and installation of gas piping systems in homes and commercial buildings is guided by a set of regulations called NFPA 54 — the National Fuel Gas Code. The code, which establishes minimum safety requirements, is also used by forensic engineers to evaluate an explosion to determine cause and responsibility. (more…)

  7. Crane Balancing Act

    Leave a Comment

    The operation of many cranes is a balancing act — one very similar to the childhood experience of using a playground seesaw. When the equipment isn’t properly balanced, the crane may succumb to the tipping force and fall to one side. Such a tipover is more common in mobile cranes rather than fixed-tower cranes.