  1. Interpreting Industrial Incident Data – Lesson Learned

    Leave a Comment

    This is a case study about an incident I investigated involving a major upset in a distillation column.  This blog builds on the previous blogs about the Distributed Control System, DCS – Data is the Key.

    Distillation is a method of separating mixtures of compounds with differing boiling points.  Uncle Bill with his still on the hill separates ethanol, that boils at 173°F, from water that boils at 212°F.  If the mixture is heated to above 173°F, but below 212°F, the ethanol will boil, the vapor will travel up out of the unit and then can be condensed and served over ice with an olive…   Any mixture of two or more chemicals with different boiling points can be separated in this way.  The distillation (more…)

  2. WARREN WEBINAR: Property Claims Issues at Manufacturing Facilities

    Leave a Comment

    LIVE WEBINAR: “Property Claims Issues at Manufacturing Facilities” | Presented by WARREN’s President and Senior Consulting Engineer, Jennifer Morningstar, P.E., CFEI.

    COURSE LEARNING OBJECTIVES
    The learning objectives of this course are to provide the attendees with information on the four major facets of property claims that are commonplace in manufacturing facilities.

    They are:

    1. Subrogation against third parties;
    2. Boiler & machinery vs property claims;
    3. Scope of loss, and
    4. Business interruption

    Each facet will be explored and exemplified by at least one case study.

    (more…)

  3. Graphitic Corrosion – Difficult to determine before a failure!

    Leave a Comment

    Graphitic corrosion is a process that may happen in equipment made of iron, particularly grey cast iron, but also ductile cast iron. Graphitic corrosion can lead to unexpected catastrophic failure of the affected part because the cast iron can lose its strength without a visible warning such as a change in size, shape, or appearance. (more…)

  4. Improper Design Leads to Fatigue Failure In Blower Shaft

    Leave a Comment

    A blower used to exhaust air from an industrial process stopped functioning when the blower wheel drive shaft fractured.  The process, and thereby most of the plant, had to operate at a reduced volume until the blower wheel could be replaced.  The blower wheel had been installed during a shutdown a week before the incident.  The blower wheel was a spare installed when the existing blower wheel was sent for scheduled remanufacturing. (more…)